Direct-lift HR8000 User Manual Page 15

  • Download
  • Add to my manuals
  • Print
  • Page
    / 32
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 14
TWO COLUMN 8K FLOOR PLATE LIFT CO7589 IN50014 Rev. D 03/2/2010
15
Warning: – the wiring must comply with local code. Have a certified electrician make the
electrical hook-up to the power unit. Protect each circuit with time delay fuse or circuit
breaker; 208v-230v single phase 60 Hz 30 amp.
STEP 22: Do not place any vehicle on the lift at this time. Cycle the lift up and down several
times to insure latches click together and all air is removed from the system. To lower the lift,
both latch releases must be manually released. Latches will automatically reset once the lift
ascends approximately 17” from base. If latches click out of sync, tighten the cable on the one
that clicks first.
STEP 23: With lift fully lowered, recheck power unit fluid level. Fill as required.
OWNER / EMPLOYER RESPONSIBILITIES
The Owner / Employer:
Shall ensure that lift operators are qualified and that they are trained in the safe use and operation of
the lift using the manufacturer’s operating instructions; ALI/SM01-1,
ALI Lifting it Right safety manual;
ALI/ST-90
ALI Safety Tips card; ANSI/ALI ALOIM-2000, American National Standard for Automotive
Lifts-Safety Requirements for Operation, Inspection and Maintenance
; ALI/WL Series, ALI Uniform
Warning Label Decals/Placards
; and in the case of frame engaging lifts, ALI/LP-GUIDE, Vehicle Lifting
Points/Quick Reference Guide for Frame Engaging Lifts
.
Shall establish procedures to periodically inspect the lift in accordance with the lift manufacturer’s
instructions or ANSI/ALI ALOIM-2000,
American National Standard for Automotive Lifts-Safety
Requirements for Operation, Inspection and Maintenance
; and The Employer Shall ensure that lift
inspectors are qualified and that they are adequately trained in the inspection of the lift.
Shall establish procedures to periodically maintain the lift in accordance with the lift manufacturer’s
instructions or ANSI/ALI ALOIM-2000,
American National Standard for Automotive Lifts-Safety
Requirements for Operation, Inspection and Maintenance
; and The Employer Shall ensure that lift
maintenance personnel are qualified and that they are adequately trained in the maintenance of the lift.
Shall maintain the periodic inspection and maintenance records recommended by the manufacturer or
ANSI/ALI ALOIM-2000,
American National Standard for Automotive Lifts-Safety Requirements for
Operation, Inspection and Maintenance
.
Shall display the lift manufacturer’s operating instructions; ALI/SM 93-1,
ALI Lifting it Right safety
manual; ALI/ST-90
ALI Safety Tips card; ANSI/ALI ALOIM-2000, American National Standard for
Automotive Lifts-Safety Requirements for Operation, Inspection and Maintenance
; and in the case of
frame engaging lifts, ALI/LP-GUIDE,
Vehicle Lifting Points/Quick Reference Guide for Frame Engaging
Lifts
; in a conspicuous location in the lift area convenient to the operator.
• Shall not modify the lift in any manner without the prior written consent of the manufacturer.
Shall provide necessary lockout/tagout means for energy sources per ANSI Z244.1-1982 (R1993),
Safety Requirements for the Lockout/Tagout of Energy Sources, before beginning any lift repairs.
Page view 14
1 2 ... 10 11 12 13 14 15 16 17 18 19 20 ... 31 32

Comments to this Manuals